GE Inspection Technologies



WL 3000 SE

WL 3000 SEThe water cooling pump WL 3000 SE is used for direct cooling of ISOVOLT-unipolar x-ray tube housings and ERESCO- radiating units. The water cooling pump WL 3000 SE is used in cases in which a direct connection to the water supply is impossible or economically not feasible. The cooling pump should also be used when contamination or high lime concentration in the water supply prohibits use of direct cooling. All parts likely to be affected by the cooling water are made of stainless steel, or of a non-corroding alloy. Equipped with fail-safe water turbine flow rate monitor. A thermostat switch is monitoring the temperature of the cooling water. Continuous operation of ISOVOLT unipolar x-ray tube housings (depending on ambient temperature an tube power). The cooling output depends on the ambient temperature, on the temperature of the return-flow cooling water, and also on the flow rate. It amounts 3000 W at the temperature difference of 11.5 K between water outlet- and ambient temperature. In practice, the cooling capacity of the WL 3000 SE at up to 25C ambient temperature is sufficient for continuous operation (100% duty cycle) of ISOVOLT unipolar x-ray tube housings (up to 3000 W).

The water cooling pump WL 3000 SE consists of the following components:

  • 1 storage tank
  • 1 radial ventilators
  • 1 thermostat
  • 1 fail-safe water flow rate monitor
  • 1 radiators
  • 1 protective housing
  • 1 electro motor and pump unit
  • 1 connecting cable, 10 m (32 ft) long with plug-in connection

 

Technical Data:
Dimensions and Weights
Length 479 mm (18.85 inch)
Width 398 mm (15.67 inch)
Height 481 mm (18.94 inch)
Weight Approx. 38.2 kg (62.05 lbs) without water
Tank Capacity Approx. 3.71
Output Data
Cooling Output See Power Diagram
Circulation Rate 6.0 1/min at 6.0 bar
Mains Voltage 230 V +/- 10%, 50/60 Hz
Power Input 2.5 A
Noise Level 55 dBA at 50 Hz, measured at a 1 m distance 56 dBA at 60 Hz, measured at a 1 m distance
Environmental Conditions:
Operating Temperature Range +5C … +40C
Storage Temperature Range -25C … +70C (storage without water)
Relative Humidity Range 20% … 80%
Settings
Maximum Pressure 8.0 bar
Water Temperature Max 35C

  

Product Item No.  
WL3000 SE - Call 1-800-962-1788 for More Info

 



WL 1001 WL 1001

The water cooling pump WL 1001 is used for direct closed-circuit water cooling of ERESCO tube heads. The WL 1001 is used in cases in which a direct connection to the water supply is impossible or economically not feasible. The cooling pump should also be used when contamination or high lime concentration in the water supply prohibits use of direct cooling. The cooling output depends on the ambient temperature, on the temperature of the return-flow cooling water, and also on the flow rate. All parts likely to be affected by the cooling water are made of stainless steel, or of a non-corroding alloy. Equipped with a fail-safe water turbine flow rate monitor.

The water cooling pump WL 1001 consists of the following components:

  • 1 storage tank (1.5 liter capacity)
  • 1 thermostat
  • 1 radiator
  • 1 electric motor with PROCON pump
  • 1 ventilator
  • 1 fail-safe water turbine .ow rate monitor *)
  • 1 protective housing

 

Technical Data:
Power Supply 230 V / 50 Hz / 0.18 kVAor115 V / 60 Hz / 0.18 kVA
Max Pressure approx. 6.0 bar (at 22C)
Flow Rate approx. 5.1 l /min at 4 bar outlet pressure
Dimensions 295 x 330 x 315 mm / 11.6 x 13 x 12.4 (W x D x H)
Weight 24 kg / 53 lbs (.lled ; incl. 10 m / 32 ft cable)
Finish All parts likely to be affected by the cooling water are made of stainless steel, or of a non-corroding alloy
Water Connector -inch water connection (optionally fast access connectors)
1 connecting cable 10 m / 32 ft long (optionally up to 100 m / 320 ft max.)
*) the 230 V version is equipped with a fail-safe water turbine flow rate monitor;
the 110 V version is equipped with a water flow switch only

  

Product Item No.  
WL1001 - Call 1-800-962-1788 for More Info

  



WLK 10


Technical Data:
Dimensions and Weight Height 485 mm / 191.1"
  Width 352 mm / 13.9"
  Length 630 mm / 24.8"
  Weight approx. 65 kg (143 lbs) without water
  Capacity 7 liters
Characteristics Cooling Power 1200 W at 25C ambient temperature (forward line temp. 15 C)1050 W at 32C ambient temperature900 W at 40C ambient temperature
  Water Flow Rate > 4.4 l/min at 4.0 bar
  Power Connection 230 V, 50/60 Hz
  Max Mains Current 7.5 A
  Noise Level < 70 dB(A) (in a distance of 1 m / 3.94”)
Environmental Conditions Operating Temperature - 5 C ... + 40 C (with antifreeze filling)
  Storage Temperature - 25 C ... + 70 C (with antifreeze filling)
  Humidity 20 % ... 80 %
Coolant Circuit Cooling Agent R 134A (CFC-free)
Settings Pressure < 6.2 bar at 50 Hz
  Forward Line 18 C
  Max Temperature 35 C
Connecting Cable 3 x 1.5 mm2; Grounding plug; 10 m (32 ft) length

  

Product Item No.  
WLK 10 - Call 1-800-962-1788 for More Info

  



WLK 31

WLK 31The WLK 31 is an air-cooled refrigeration aggregate designed to facilitate anode heat dissipation of the x-ray tube when operating at high ambient temperatures (up to 40C) and can also be used when, for economical reasons cooling of the x-ray tube from the water supply is not feasible. The aggregate is mounted in a square tube frame and is mobile on 4 casters. Filled with CFC-free coolant and equipped with a fail-safe water turbine flow rate monitor for our x-ray equipment ISOVOLT series.

Technical Data:
Cooling Power 3000 W at 40 C ambient temperature
Water Flow Rate > 6 l/min at 4.0 bar
Power Connection 230 V 10 %, 50/60 Hz, 9.3 A
Connecting Cables 3 x 1.5 mm2, length 10 m (32 ft), power plug 5 x 1.5 mm2, length 10 m (32 ft), Schaltbau plug
Water Connection diameter 12 mm (0.5”), thread 1/2“
Operating Temperature + 0 C ...+ 40 C
Storage Temperature - 25 C ... + 70 C (with cooling agent)
Relative Humidity 20 % ... 90 %
Capacity 14 liters (without hoses)
Cooling Agent R 134a (CFC-free), capacity 1.3 kg (2.86 lbs)
Dimensions 612 x 590 x 925 mm (24.1” x 22.2” x 36.4”) (WxDxH)
Weight 115 kg (253 lbs) (without connecting cables, without water)
Noise Level < 65 dBA in a distance of 1 m (3.2 ft)
Noise Level Pump Only 55 dB; at 1 m distance
Compressor Type Motor CAJ 4515 A
Rated Speed 1 PS 230 V
Oil 2900 min-1
Max Operation Current SHELL Clavus 887 cm3
Default Settings max. pressure < 6.7 bar
flow rate monitor OFF 4.0 l/min
water forward line (T1) 25 C
cooling agent (T2) 5 C
max. temperature (T3) 35 C

  

Product Item No.  
WLK 31 - Call 1-800-962-1788 for More Info

  



OW 4002

OW 4002The OW 4002 is a water re-cooled oil circulation pump designed to facilitate anode heat dissipation of x-ray tubes. The heat energy produced by the x-ray tube is transferred via an oil/water heat exchanger. The cooling aggregate is designed for re-cooling of tube-cooling oil for bipolar x-ray tubes. The water-cooled oil circulation pump system can cool x-ray tubes with 4200 W anode heat dissipation under conditions of constant operation if sufficient flow of cooling water at a low enough temperature is available. A thermostat valve controls the oil temperature and minimizes water consumption. If, for economical or technical reasons, a re-cooling of the tube-cooling oil from the water supply is not feasible, we recommend an air-re-cooled oil circulation pump. The OW 4002 is equipped with a fail-safe turbine flow rate monitor.

Function:
The hot tube-cooling oil returns via the oil flow switch through the oil/water heat exchanger and - after cooling down – into the oil reservoir. The oil reservoir is vented to the atmospheric pressure. The circulation pump drains the oil from the reservoir and feeds it to the oil outlet connector. The cooling water is supplied to and returned from the x-ray tube through two hose connectors.

Electrical Control:
The OW 4002 cooling pump is connected by a 5-wire connecting cable supplying the circulation pump from the x-ray control unit and connects the safety circuits to the control to ensure safe operation of the x-ray tube.

Safety Circuit:
The safety circuit monitors the cooling oil supply to the x-ray tube. The circuit includes a fail-safe oil turbine flow rate monitor, which opens the circuit in case a minimum flow rate of the cooling oil (17 l/min) is not ensured. A thermostat switch opens the circuit in case the cooling water temperature exceeds the set temperature (50C). Both switches reconnect automatically after safe cooling is ensured.

Water Supply:
The heat dissipated from the X-Ray tube and also the dissipation heat from the drive of the pump has to be transferred by the oil/water heat exchanger to the cooling water. The water flow is controlled by a thermostat to maintain a constant oil temperature of 40C. This, however, can only be accomplished if sufficient water flow rate and water temperature (see diagram) are provided.

Technical Data:
Dimensions and Weight
Width 621 mm / 24.44 inch
Depth 350 mm / 13.8 inch
Height 551 mm / 21.7 inch
Weight approx. 45 kg / 99 lbs (w/o oil)
Capacity 23 l (operation .lling)
Oil Connection Non-interchangeable quick-action couplings
Water Hose Connection NW 10 mm
Connecting Cable 10 m / 32 ft long with plug connection
Power Data  
Cooling Capacity 4200 W (see diagram)
Oil Circulating Quantity > 17 l/min at 3,5 bar based on oil temperature 22C 3C
Cooling Oil S 5585
Power Supply 230 V 10% / 50/60 Hz
Charging Rate 3.6 A at 6 bar
Max Noise Level < 55 dBA
Protection Class IP 54
Environment Conditions  
Operating Temperature +5C...+40C
Storage Temperature -40C...+70C (w/o oil)
Relative Humidity 20%...80%
Default Settings  
Maximum Pressure 9.5 bar
Oil-.OW Monitor (Open) 14 l/min
Cooling Water Controller 40C
Thermostat 50C

  

Product Item No.  
OW 4002 - Call 1-800-962-1788 for More Info

  



OL 4503

OL 4503The OL 4503 is an air re-cooled oil circulation pump designed to facilitate anode heat dissipation of bipolar x-ray tubes when for economical or technical reasons a re-cooling of the tube-cooling oil from the water supply is not feasible. The air-cooled oil circulation pump system is suitable for normal temperature climate and can cool x-ray tubes with 4500 W anode heat dissipation up to an ambient temperature of approx. 32C. The design allows the cooling pump to transfer the heat from the x-ray tubes to the ambient air. Therefore, sufficient fresh, cool air supply must be guaranteed. The OL 4503 is equipped with a fail-safe turbine flow rate monitor.

Function:
The hot tube cooling oil returns via the oil flow switch and through the air-cooled radiator/heat exchanger and, after cooling down, into the oil reservoir. The oil reservoir is vented to the atmospheric pressure. The circulation pump drains the oil from the reservoir and feeds it to the oil outlet quick-lock connector, via the thermostat probe.

Electrical Control:
The OL 4503 cooling pump is connected by a 5-wire connecting cable supplying the circulation pump from the x-ray control unit with 230 V 50/60 Hz and connects the safety circuits to the control to ensure safe operation of the x-ray tube.

Safety Circuit:
The safety circuit monitors the cooling oil supply to the x-ray tube. The circuit includes a fail-safe oil turbine flow rate monitor, which opens the circuit in case a minimum flow rate of the cooling oil (22 l/min) is not ensured. A thermostat switch opens the circuit in case the cooling oil temperature exceeds the set temperature (55C). Both switches reconnect automatically after safe cooling is ensured.

Air Supply:
The heat dissipated from the x-ray tube and also the dissipation heat from the drive of the pump and ventilator has to be discharged by the air cooled radiators. If the unit is operated in a small, self-contained room the room temperature will built up rapidly. As shown in the below diagram the cooling capacity decreases with increasing ambient temperature. It is therefore important that sufficient cool air supply is provided for the OL 4503.

Technical Data:
Power Supply Requirements 230 V 10%, 50/60 Hz
Power Input 0,785 kW (Pmax ; 230 V; 50 Hz)1,058 kW (Pmax ; 230 V; 60 Hz)
Oil Connection Non-interchangeable quick-action couplings
Cooling Capacity 4500 W (see diagram)
Cooling Oil S 5585
Capacity 23 liters
Oil Circulation Quantity > 22 l at 3.5 bar
Connecting Cable 10 m (32 ft) long with plug-in connection
Dimensions 650 x 350 x 750 mm / 26,0 x 13.8 x 29.5 inch (WxHxD)
Weight approx. 54,5 kg / 120 lbs (w/o oil)
Max Noise Level 63 dB(A) at 50 Hz 67 dB(A) at 60 Hz
Operating Temperature -10...+40C
Storage Temperature -25...+70C
Relative Humidity max.90%
Default Settings  
Oil-Flow Monitor 17 l / min
Thermostat 55 3C
Maximum Pressure 9 + 0,5 - 0,2 bar

 

Product Item No.  
OL 4503 - Call 1-800-962-1788 for More Info

 



OLK 50

OLK 50The OLK 50 is an air-cooled refrigeration aggregate designed to facilitate anode heat dissipation of the x-ray tube when operating at high ambient temperatures (up to 40 C) and can also be used when, for economical reasons a re-cooling of the tube-cooling oil from the water supply is not feasible. The design allows the cooling aggregate to transfer the heat from the x-ray tubes to the ambient air. Therefore, sufficient fresh air supply must be guaranteed. For operation at up to approximately 20C we recommend the oil cooling pump OL 4503. If re-cooling from the water supply is available, the oil cooling pump OW 4002 is recommended. The aggregate is mounted in a square tube frame and is mobile on 4 casters. The OLK 50 is equipped with CFC-free coolant.

Function:
The cooling aggregate is designed for re-cooling of tube-cooling oil for bipolar x-ray tubes. The air-cooled aggregate is suitable for tropical climate and can be operated at an ambient temperature of up to 40 C. A circulation pump for the cooling oil, a reservoir (approximately 25 l) and safety devices for maximum oil temperature (55 C) and minimum circulation flow rate (17l/min) are completely wired, installed in the aggregate and connected. The aggregate is mounted in a square tube frame and is mobile on 4 casters. The hot tube cooling oil returns via the oil flow switch and through the heat exchanger and, after cooling down, into the oil reservoir. The oil reservoir is vented to the atmospheric pressure. The circulation pump drains the oil from the reservoir and feeds it to the oil outlet quick-lock connector, via the thermometer probe.

Cooling Circuit:

  • The cooling circuit consists of
  • Full-hermetic compressor
  • Air cooled condenser
  • Cooling agent dryer
  • Cooling agent viewing glass with hygroscope
  • Expansion valve
  • Evaporator/heat exchanger
  • High and low pressure regulator
  • Corresponding quick-lock connectors

All mobile components of the compressor, including the drive motor, are hermetically sealed in a housing. The surface of the air-cooled condenser has generous dimensions to ensure reliable operation even at high evaporation and ambient temperatures. The ambient air is taken in through the condenser by means of the ventilator and is expelled via the compressor through the protective grill. Inverse rotation of the ventilator would reduce the air flow rate drastically, thus reducing the cooling capacity of the aggregate. The cooling agent liquefied in the condenser gets to the expansion valve after passing through the oil reservoir, the dryer and the viewing glass. Here the pressure is released from the condenser to the evaporator pressure. In the heat exchanger the heat required for this expansion is taken from the hot cooling oil. The expansion valve controls the flow of cooling agent required to cool to a certain temperature sensed at the heat exchanger’s output side.

Electrical Control:
The standard version of the cooling aggregate is sized for connection to a 400 V 50 Hz / 440 V 60 Hz three-phase power supply and is connected to the power via a 5-wire power cable. The live leads are labeled R/S/T to be connected to the phases, the blue conductor to the neutral (Mp) and the green/yellow to ground. A second 5-wire connecting cable supplies the circulation pump from the x-ray control unit and connects the safety circuits to the control to ensure safe operation of the

Safety Circuit:
The safety circuit monitors the cooling oil supply to the x-ray tube. The circuit includes an oil flow switch, which opens the circuit in case a minimum flow rate of the cooling oil (17 l/min) is not ensured. A thermostat switch opens the circuit in case the cooling water temperature exceeds the set temperature (55C). Both switches reconnect automatically after safe cooling is ensured.

Air Supply:
The heat absorbed by the heat exchanger and also the dissipation heat from the drive of the compressor has to be discharged by the air cooled condenser. If the unit is operated in a small, self-contained room the room temperature will built up rapidly. As shown in the overleaf diagram the cooling capacity decreases with increasing ambient temperature. It is therefore important that sufficient air circulation is provided for the OLK.

Maintenance:
All components of the cooling aggregate are selected to be maintenance-free. However, it is crucial that the condenser be kept clean. Also, the cooling oil level in the oil reservoir should be observed and topped up if required.

Technical Data:
Dimensions and Weights
Height 925 mm / 36.4”
Width 612 mm / 24.1”
Length 590 mm / 23.2”
Weight approx. 180 kg / 396 lbs without oil
Capacity 25 liters
Characteristics
Cooling Power 5000 W at 32C ambient temperature
Oil Flow Rate > 22 l/min at 4.0 bar
Power Connection 3N PE 400/230 V, 50 Hz
Max Mains Current 8.2 A
Noise Level < 70 dBA (in a distance of 1 m (3.2 ft))
Environmental Conditions
Operating Temperature + 5 C ... + 40 C
Storage Temperature - 25 C ... + 70 C (with antifreeze .lling)
Humidity 20 % ... 80 %
Coolant Circuit
Cooling Agent R 22 (CFC-free)
Settings
Pressure max. 9.25 bar
Flow Rate Monitor Off 17 l/min
Oil Forward Line (T1) 20 C
Temperature (T2) 40 C
Compressor
Type TAH 4518 A
Motor 0.55 kW
Rated Speed 2900 min-1
Connecting Cable
5 x 1.5 mm2 Grounding plug, length 10 m (32 ft)
5 x 1.5 mm2 CECON plug, length 10 m (32 ft)

 

Product Item No.